Comprehensive Guide to Using RISEY DPF Cleaning System: Tips, Techniques, and Key Advantages

  • Writer: RISEY
    RISEY
  • 5 days ago
  • 6 min read
RISEY V-02 & V-03
RISEY V-02 & V-03

Key Advantages

No Cutting Required

  • Regeneration without disassembling the DPF core, ensuring a completely non-destructive high-temperature cleaning process.

 

Low Operating Cost

  • Consumes only 1.2 kWh electricity + 2–4 liters of fuel per hour, significantly reducing operating expenses.

 

Flexible Temperature Control

  • Three-stage regeneration process:

    • Initial stage: 200°C 

    • Mid stage: 400°C 

    • Final stage: Adjustable temperature up to required level 

  • Ensures optimal cleaning performance while reducing total regeneration time to within 30 minutes.

  • Cooling time is extremely fast — from 600°C down to 50°C in just 3 minutes.

 

Multi-Functional System

  • Back pressure testing

  • High-temperature regeneration

  • Dust blowing / air purge

  • Pulse blast cleaning function

  • IoT remote control via mobile device

  • Over-temperature warning system

  • Ignition fault alert system

  • Heat Wave Micro-Pulse Technology: Intelligent cooling system (V-03)

  • AI Automatic Temperature Control (V-02PRO / V-03)

  • High-Power Fan (V-03)

  • European and Japanese Imported Components (V-03)

Ensures maximum safety and operational reliability.

 

Outstanding Cleaning Performance

  • During regeneration, the system automatically activates high-temperature & high-pressure air purge, preventing carbon buildup retention.

  • After regeneration, automatic or manual pulse blasting ensures complete removal of residual carbon deposits.

 

System Design & Features

  • HD Touchscreen Interface


    User-friendly operation with all functions accessible via an intuitive control panel.

  • Industrial Design Structure


    Clean, robust exterior with optimized functional layout for easier operation.

  • One-Button Operation


    Fully automated regeneration process.

 

Advanced Control System

  • Equipped with programmable PLC control system 

  • Multi-stage temperature control with PID precision regulation 

  • Automatic heating and cooling programs for enhanced stability and safety. 

  • IoT Integration


    Supports remote operation via mobile devices.

  • Energy Efficient Heating


    Up to 50% more energy efficient compared to traditional heating tube systems.

  • Fast Performance 

    • Regeneration time: < 30 minutes 

    • Cooling: 600°C → 50°C in 3 minutes 

  • Pulse Blast Cleaning System


    Ensures complete removal of ash and carbon residues.

 

Operation Process

  1. Power on the machine

  2. Set the regeneration program

  3. System runs automatically

  4. Automatic shutdown after completion

 

Why Choose Them?

Efficient • Energy-saving • Easy to operate • Fast heating • Flexible control • Superior performance


 

Product Application

The Intelligent DPF Regeneration Machine is a user-friendly, fully automated DPF cleaning device. It is suitable for buses, trucks, and heavy-duty vehicles that meet the following emission standards:

  • China IV / V / VI 

  • Euro IV / V / VI 

  • North American EPA Tier 4 / US 2010 

The device effectively removes carbon deposits and particulate matter from their after-treatment DPF systems, restoring them to optimal condition.

Non-Destructive Cleaning:High-temperature precision cleaning disintegrates carbon deposits from inside the DPF without any disassembly, restoring DPF components to optimal condition.

  • Complete Regeneration:


    Ensures that the DPF system is fully regenerated and operating efficiently.

 

Important Safety Instructions

  1. This is a fuel-powered high-temperature device. Always have a trained operator present during use. Keep away from flammable or explosive materials, and maintain a safe distance from people to prevent burns.

  2. Set appropriate temperatures based on DPF type and level of blockage. Incorrect settings may cause DPF carriers to crack or melt.

  3. Wear protective gear when placing or removing components, and ensure they are handled smoothly and stably.

  4. Check temperature readings before each startup to ensure they are within the normal range.

  5. Outdoor use is recommended. If used indoors, proper ventilation must be installed.

Only operate the machine after fully understanding these precautions. The manufacturer is not responsible for any consequences resulting from improper use.

 

Special Notice During Regeneration

  • After starting the regeneration process, check the exhaust outlet for gas emission.

  • If back pressure is too high, set the regeneration temperature to around 200°C initially for preliminary clearing, until gas is visibly emitted from the exhaust.


 

Operating Environment

  1. Ambient Temperature: 0°C – 50°C

  2. Relative Humidity: 0% – 65%

  3. Environment Requirements: Well-ventilated, vibration-free, dust-free, and free from flammable gases, oil mist, or dripping water.

  4. Safety Distance: Keep all flammable and explosive materials at least 1 meter away from the device.

  5. Placement Recommendation: Preferably in an outdoor workspace; if used indoors, ensure proper ventilation is installed.

 

Setup and Safety Instructions

  • After unpacking, move the device and install its casters for easy mobility.

  • Power Connection: Use a household 220V power source. Recommended cable: ≥ 2.5 mm².

  • Fuel Tank: The device has a built-in fuel tank. When the fuel level is below the lower limit, it will automatically alarm and display a warning message on the screen.

  • Check Safety Status: Ensure all meters indicate a safe power-on state. Set the switch knob to NO, and voltage meter should display around 220V.

  • Power On: Turn on the main power switch. The touchscreen will light up normally. Do not press the emergency stop button.

  • Temperature Check: Verify that the real-time temperature reading matches the current ambient temperature.

 

DPF Regeneration Process

  1. Placement of DPF Components: 

    • Place the DPF safely and securely on the movable workstation.

    • Seal sensor holes with screws and cover the urea inlet with high-temperature tape.

  2. Connection: 

    • Use the high-pressure thermal converter with the appropriate fixture to connect the DPF.

    • Ensure the fixture is safely and tightly locked.

  3. Set Regeneration Parameters: 

    • Input desired temperature and time for regeneration.

  4. Start Regeneration: 

    • Press the “Start Regeneration” button on the main interface or the start button below.

    • The process will automatically complete.

  5. Cooling & Removal: 

    • When the real-time temperature naturally drops below ~100°C, the machine will delay stop automatically.

Main Interface Operation Guide
Main Interface Operation Guide
  1. Target Temperature – The set temperature for DPF regeneration.

  2. Actual Temperature – The current temperature of the DPF.

  3. Pressure Detection – Measures the exhaust pipe pressure.

  4. Total Runtime – Displays the total operating time of the device.

  5. Regeneration Time – Starts timing once the temperature reaches the target value.

  6. Real time Pressure – Real-time dynamic backpressure of the exhaust pipe.

  7. Regeneration Start – Press to automatically complete the regeneration based on the set temperature and time. Can also be started using the panel start button.

  8. Intelligent Cooling On – The fan turns on automatically when it gets too hot, keeping the DPF safe.

  9. Reset – Restores the device to factory settings.

  10. Cooling Start – Manually turn the fan on or off. Cannot be turned off during the regeneration process. 

  11. Start Detection – Starts real-time exhaust pressure monitoring.

  12. Settings – Opens the parameter configuration interface.


Parameter Settings Guide
Parameter Settings Guide
  1. Initial Temperature – Default: 200°C (No need to modify)

  2. Mid-Section Temperature – Default: 400°C (No need to modify)

  3. Regeneration Temperature – Default: 800°C. Can be adjusted freely according to the size and structure of the exhaust pipe.

  4. Holding Time – Default: 1 minute (No need to modify)

  5. Regeneration Time – Default: 60 minutes. Can be set based on the degree of exhaust pipe blockage.

  6. Fan Delay – After regeneration, the fan automatically starts. This is the cooling time for the fan, default: 4 minutes (No need to modify)

  7. Pulse Blast Mode (Manual / Automatic) – Select the desired pulse blast mode according to operational needs.




U-Shaped Exhaust Pipe

U-Shaped Exhaust Pipe
U-Shaped Exhaust Pipe

Regeneration Temperature: 750–800°C

Regeneration Time: 80–90 minutes

Cooling Time: 15–25 minutes

Important Note: Large urea crystal deposits must be manually removed before regeneration to ensure optimal performance.

Square Exhaust Pipe

Square Exhaust Pipe
Square Exhaust Pipe

Regeneration Temperature: 750–800°C

Regeneration Time: 60–90 minutes

Cooling Time: 15–25 minutes

Important Note: Large urea crystal deposits must be manually removed before regeneration to ensure optimal performance.

Round Exhaust Pipe

Round Exhaust Pipe
Round Exhaust Pipe

Regeneration Temperature: 700–800°C

Regeneration Time: 50–80 minutes

Cooling Time: 15–20 minutes

Important Note: Large urea crystal deposits must be manually removed before regeneration to ensure optimal performance.

Oval Exhaust Pipe

Oval Exhaust Pipe
Oval Exhaust Pipe

Regeneration Temperature: 700–750°C

Regeneration Time: 40–70 minutes

Cooling Time: 10–15 minutes

Important Note: Large urea crystal deposits must be manually removed before regeneration to ensure optimal performance.

Euro VI/EPA Tier 4 Exhaust Pipe

 

Euro VI/EPA Tier 4 Exhaust Pipe
Euro VI/EPA Tier 4 Exhaust Pipe

Regeneration Temperature: 650–750°C

Regeneration Time: 40–60 minutes

Cooling Time: 10–15 minutes

Important Note: Large urea crystal deposits must be manually removed before regeneration to ensure optimal performance.

Detachable DPF

Detachable DPF
Detachable DPF

Regeneration Temperature: 690–700°C

Regeneration Time: 30–40 minutes

Cooling Time: 10–15 minutes

Important Note: Must be used with the appropriate fixture.


Frequently Asked Questions (FAQ) & Solutions

No.

Problem

Solution

1

Device does not work

1. Check that the power cable is properly connected.2. Ensure all switches and indicator lights are in the ON position.

2

No response when starting

1. Check if the emergency stop button is pressed.2. Verify air pressure is sufficient and temperature display is working.

3

Regeneration has no effect

Check if the set temperature and time are appropriate; increase temperature and regeneration time if necessary.

4

Touchscreen is unresponsive

1. Check if the distribution box temperature is too high or ambient temperature is too low.2. Power off and restart, and allow for cooling.

5

Fuel level alarm

Refill fuel promptly.

6

Ignition failure

Check the fuel system and inspect the ignition plug.

7

Post-installation alarm on China VI vehicles

Perform one self-regeneration cycle on the vehicle to clear the alarm.


Device Packing Accessories

No.

Item

Specification

Quantity

1

Main unit with one thermal converter

Set

1 unit

2

Special Connection Fixture

Set

2 sets

3

Pulse blast pipe

Set

1 set

4

Wheel sets with screws

Pc

4 Pcs

5

Fuel tank cover with screws

Pc

1 Pc

6

Fan hose with clamps

Set

1 set

7

DPF carrier fixture

Set

1 set

8

Exhaust pipe reducers (large and small)

Set

1 set

9

Pipe clamp

Set

1 set


 
 

Contact Us

  • Whatsapp
  • Facebook
  • Youtube
  • Instagram
  • TikTok

Opening Hours(GMT+8)

Mon - Fri

8:00 am – 8:00 pm

Saturday

9:00 am – 8:00 pm

​Sunday

9:30 am – 8:00 pm

Location

International Financial Center, Tianfu New Area, Chengdu City, Sichuan Province, People's Republic of China

© 2026 Risey Technology. All Rights Reserved.

| Privacy Policy | Terms of Use

Follow Us

bottom of page